Model
|
FKC
|
FKG
|
FKA
|
Range
|
kPa (mbar)
1(10), 6(60), 32 (320),
130 (1300), 500(5000),
3000(30000), 20000(200000)
|
kPa (bar)
130 (1,3), 500 (5), 3000 (30), 10000 (100), 50000 (500) |
kPa (bar)
16 (0,16), 130 (1,3), 500 (5) 3000 (30), 10000 (100)
|
Standard Rangeability
|
100:1 depending of the span
|
||
Accuracy of adjusted span
|
Upto ±0.04%/Standard ±0.065%
|
||
Temperature Limits
|
-40 to 120°C (process)/-40 to +85°C (Ambient)
|
||
Wetted Parts
|
SS316L / Hastelloy C / Monel / Tantalum
|
||
Output
|
4-20mA dc + HART protocol
|
||
Power Supply
|
10.5 to 45 VDC
|
||
Communication
|
Fuji / Hart® protocols (standard) / Fieldbus Foundation H1 protocols (option)
|
||
Environmental Protection
|
IEC IP67 and NEMA 4X
|
||
Hazardous Area certifications
|
Flame proof areas and intrinsic safety (ATEX, FM, CSA, etc)
|
||
Available Functions
|
1/ Burnout according NAMUR NE43 recommandation
2/ Linearization function (14 points) to linearize the output signal
|
Model
|
FKP
|
FKH
|
|
Range
|
kPa (bar)
130 (1,3), 500 (5), 3000 (30),
10000 (100)
|
kPa (bar)
130 (1,3), 500 (5), 3000 (30) |
|
Standard Rangeability
|
16:1 depending of the span
|
||
Accuracy of adjusted span
|
±0.1% ±0.2%
|
||
Temperature Limits
|
-40 to 100°C (process)/-40 to +85°C (Ambient)
|
||
Wetted Parts
|
SS316L
|
||
Output
|
4-20mA dc + HART protocol
|
||
Power Supply
|
10.5 to 45 VDC
|
||
Communication
|
Fuji / Hart® protocols (standard) / Fieldbus Foundation H1 protocols (option)
|
||
Environmental Protection
|
IEC IP67 and NEMA 4X
|
||
Hazardous Area certifications
|
Flame proof areas and intrinsic safety (ATEX, FM, CSA, etc)
|
||
Available Functions
|
1/ Burnout according NAMUR NE43 recommandation
2/ Linearization function (14 points) to linearize the output signal
|
Model
|
FKB/D/M
|
FKE
|
FKH/P
|
Range
|
Depending of transmitter version
|
kPa (mbar)
32 (320), 130 (1300), 500 (5000) |
kPa (bar)
130 (1,3), 500 (5), 3000 (30) 10000 (100)
|
Standard Rangeability
|
100:1 depending of the span 100:1 depending of the span 16:1 depending of the span
|
||
Accuracy of adjusted span
|
±0.065% (DP & relative press.), ±0.165% /(0,1% optional) ±0.1% or ±0.2%
0,2% (absolute pressure)
|
||
Temperature Limits
|
-90 to +400°C (process) -40 to +150°C (process) -40 to +150°C (process)
-40 to +85°C (ambient) -40 to +85°C (ambient) -40 to +85°C (ambient)
|
||
Wetted Parts
|
SS316L / Hastelloy C / Monel / Tantalum
|
||
Output
|
4-20mA dc + HART protocol
|
||
Power Supply
|
10.5 to 45 VDC
|
||
Communication
|
Fuji / Hart® protocols (standard) / Fieldbus Foundation H1 protocols (option)
|
||
Environmental Protection
|
IEC IP67 and NEMA 4X
|
||
Hazardous Area certifications
|
Flame proof areas and intrinsic safety (ATEX, FM, CSA, etc)
|
||
Available Functions
|
1/ Burnout according NAMUR NE43 recommandation
2/ Linearization function (14 points) to linearize the output signal
|